Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 55(15): 3958-65, 2016 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-27411121

RESUMO

This paper shows the opto-mechanical design of a new filter radiometer built at the Physikalisch-Technische Bundesanstalt, Germany, for the accurate determination of the thermodynamic temperature of high-temperature blackbodies. The filter radiometer is based on a three-element reflection-type trap detector that uses three large active area silicon photodiodes. Its spectral coverage and field of view are defined by a detachable narrow-band filter and a diamond-turned precision aperture, respectively. The temperature of the filter radiometer is stabilized using a water-streamed housing and is measured using a thin-film platinum thermometer placed onto the first photodiode element. The trap "mount" has been made as compact as possible, which, together with the large active area of the chosen photodiodes, allows a wide field of view. This work presents the design of the filter radiometer and discusses the criteria that have been considered in order for the filter radiometer to suit the application.

2.
Philos Trans A Math Phys Eng Sci ; 374(2064): 20150043, 2016 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-26903097

RESUMO

The mise-en-pratique for the definition of the kelvin at high temperatures will formally allow dissemination of thermodynamic temperature either directly or mediated through high-temperature fixed points (HTFPs). In this paper, these two distinct dissemination methods are evaluated, namely source-based and detector-based. This was achieved by performing two distinct dissemination trials: one based on HTFPs, the other based on absolutely calibrated radiation thermometers or filter radiometers. These trials involved six national metrology institutes in Europe in the frame of the European Metrology Research Programme joint project 'Implementing the new kelvin' (InK). The results have shown that both dissemination routes are possible, with similar standard uncertainties of 1-2 K, over the range 1273-2773 K, showing that, depending on the facilities available in the laboratory, it will soon be possible to disseminate thermodynamic temperatures above 1273 K to users by either of the two methods with uncertainties comparable to the current temperature scale.

3.
Philos Trans A Math Phys Eng Sci ; 374(2064): 20150044, 2016 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-26903099

RESUMO

The thermodynamic temperature of the point of inflection of the melting transition of Re-C, Pt-C and Co-C eutectics has been determined to be 2747.84 ± 0.35 K, 2011.43 ± 0.18 K and 1597.39 ± 0.13 K, respectively, and the thermodynamic temperature of the freezing transition of Cu has been determined to be 1357.80 ± 0.08 K, where the ± symbol represents 95% coverage. These results are the best consensus estimates obtained from measurements made using various spectroradiometric primary thermometry techniques by nine different national metrology institutes. The good agreement between the institutes suggests that spectroradiometric thermometry techniques are sufficiently mature (at least in those institutes) to allow the direct realization of thermodynamic temperature above 1234 K (rather than the use of a temperature scale) and that metal-carbon eutectics can be used as high-temperature fixed points for thermodynamic temperature dissemination. The results directly support the developing mise en pratique for the definition of the kelvin to include direct measurement of thermodynamic temperature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...